STC Vietnam (Song Thanh Cong Trading Service Co., Ltd.)
Hãy liên hệ với chúng tôi để được hỗ trợ tốt nhất!
Đoàn Thị Xuân Hảo
I Cellphone I : 039.868.0915
I Email I : hao@songthanhcong.com
Vaisala Vietnam | Code: HMT330 7S1D001BXAA100A1DAABAA1 |
Humidity and Temperature Transmitter; Transmitter type: HMT337 for high humidities; Probe cables: Probe 2m +180C | |
Additional temperature probe: 2m, -70..+180°C 1/4 DIN Class B | |
Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro; No display, power supply : Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA; Analog output signals for Ch1: 0...100%RH; Analog output signals for Ch2: Special (pls confirm as placing order); Output units: Metric Units; Option for module slot 1&2: no module; Cable bushings: Sealed Cable Gland M20x1.5; Transmitter installation: Wall Mounting Kit; Humidity sensor: Heated composite sensor; Sensor protection: PPS Grid with Steel Netting; No Installation Kit, No Accessories | |
Vaisala Vietnam | Humidity and Temperature Transmitter |
Code: HMT330 7S1D011BXAA100A45CQBAA1 | |
Transmitter type: HMT337 for high humidities | |
Probe cables: Probe 2m +180C | |
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display | |
Power supply: Standard with Galvanic Isolation Module | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: Special – pls confirm and make clear as order ; No Analog output signals for Ch3 | |
Analog output range for temperature: no T range | |
Output units: Metric Units; No Option for module slot 1&2 | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
Transmitter installation: DIN Rail Clips with Installation Plate | |
Humidity sensor: Heated composite sensor HUMICAP180C | |
Sensor protection: Sintered Filter AISI 316L HM47280 | |
Installation kit for probe: Swagelok for 12mm Probe 1/2" NPT Thread ; User´s Guide HMT330 English | |
No PC Accessories ; No Calibration Contract ISO9001 Calibration | |
Vaisala Vietnam | Humidity and Temperature Transmitter HMT330-3E0A001BCAX100B01ACBAA1 |
HMT333 for general use, Probe cables 2m, No Temperature Probe | |
Calculations: Code RH+T, no display, Power supply : Standard (10...35V,24VAC); Signal output: Analog Output 4...20mA, | |
Analog output signals for Ch1: Channel 1 RH (0...100%RH) | |
Analog output signals for Ch2: Temperature Range Special 0...50°C | |
Analog output signals for Ch3: No Analog Outputs | |
Output units: Metric Units | |
Option for module slot 1/ slot 2: No Module | |
Cable bushings: Cond Uit Fitting NPT 1/2" | |
Transmitter installation: No Installation Kit | |
Humidity sensor: General purpose HUMICAP180 | |
Sensor protection: PPS Grid with Steel Netting | |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 | |
Vaisala Vietnam | Code: HMT330 7S0A001BCAE200A0AACBCA1 |
Humidity and Temperature Transmitter | |
Transmitter type: HMT337 for high humidities | |
Probe cables: 2m +180C; No Additional temperature probe | |
Calculations: Code RH+T, No Display | |
Power supply: Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: Temperature Range -40...+180C | |
No Analog output signals for Ch3 | |
Output units: Non Metric Units | |
Option for module slot 1 &2: No Module | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
No Transmitter installation | |
Humidity sensor: General purpose HUMICAP180R | |
Sensor protection: PPS Grid with Steel Netting | |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English | |
PC Accessories: MI70LINK PC Software with RS232 Serial Cable with D9 Female Connector | |
No Calibration Contract ISO9001 Calibration | |
No Maintenance Contract | |
Vaisala Vietnam | Humidity and Temperature Transmitter |
Code: HMT330 7S1D001BBBB211A15ACBBA1 | |
Transmitter type: HMT337 for high humidities | |
Probe cables: Probe 2m +180C | |
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display | |
Power supply: Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: 0...100%RH | |
Analog output signals for Ch3: 0...100%RH | |
Analog output range for temperature: Temperature Range -40...+60C ; Output units: Non Metric Units | |
Option for module slot 1: Relay Module | |
Option for module slot 2: Relay Module | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
Transmitter installation: Wall Mounting Kit | |
Humidity sensor: Heated composite sensor HUMICAP180C | |
Sensor protection: PPS Grid with Steel Netting | |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English | |
PC Accessories: RS232 Serial Interface Cable with D9 Female Connector ; No Calibration Contract ISO9001 Calibration | |
No Maintenance Contract |
Không có nhận xét nào: